Tektronix AWG5002

 

Arbitrary Waveforms

 AWG5002

Waveform Length

1 to 16,200,000 points (or 1 to 32,400,000 points, option 01)

Number of Waveforms

1 to 16,000

Sequence Length

1 to 4,000 steps

Sequence Repeat Counter

1 to 65,536 or infinite.

Jump Mode

Repeat count, Trigger, Goto-N and Jump

Run Modes

Synchronous and Asynchronous

Continuous

Waveform is iteratively output. If a sequence is defined, the sequence order and repeat functions are applied

Triggered

Waveform is output only once when an external, internal, GPIB, LAN or manual trigger is received

Gated

Waveform begins output when gate is true and resets to beginning when false

Sequence

Waveform is output as defined by the sequence

Clock Generator

 

Sampling Frequency

 10 MS/s to 600 MS/s

Resolution

8 digits

Internal Clock

 

Accuracy

Within ± (1 ppm + Aging),

Aging: within ± 1 ppm / year

Clock Phase Noise

Less than -90 dBc/Hz at 100 kHz offset

Internal Trigger Generator

 

Internal Trigger Rate

 

Range

1.0 µs to 10.0 s

Resolution

3 digits, 0.1 µs minimum

Skew Control Between Outputs

 

Range

- 5 ns to + 5 ns

Resolution

5 ps

 

AWG5002

Main Arbitrary Waveform Output

 

Resolution

14 bits

Analog Output

 

(in to 50 Ω) (Twice for Hi_Z input)

Number of Arb Outputs

2

Output Style

Differential

Output Impedance

50 Ω

Connector

BNC Front

Amplitude

 

Output Voltage

Normal: -4.5 V to + 4.5 V,

Direct -0.3 V to +0.3 V

Amplitude

Normal: 20 mVp-p to 4.5 Vp-p,

Direct; 20 mVp-p to 0.6 Vp-p

Resolution

1 mV

DC Accuracy

±(2.0% of Amplitude + 2 mV) at offset = 0 V

Offset

 

(into 50 Ω)

 

Range

Normal: -2.25 V to +2.25 V,

Direct: N/A

Resolution

1 mV

Accuracy

±(2% of offset +10 mV at minimum amplitude

Pulse Response

 

Rise/Fall time: (10% to 90%).

Normal: 1.4 ns (2.0 Vp-p),

Direct: 0.95 ns (0.6 Vp-p)

Bandwidth (-3dB)

Normal: 250 MHz (2.0 Vp-p),

Direct: 370 MHz (0.6 Vp-p)

Ringing

Normal: 750 mVp-p (4.5 Vp-p filter through), 80 mVp-p (2.0 Vp-p filter through),

Direct: 60 mVp-p (0.6 Vp-p)

Low Pass Filter

High range: 100 MHz, 20 MHz,

Low range: through, 100 MHz, 20 MHz,

Direct: N/A

Delay from Marker

Normal: 17.5 ns to 19.4 ns (20 MHz filter),

3.8 ns to 5.7 ns (100 MHz filter),

0 to 1.9 ns (Through),

Direct: -1.5 ns to 0.4 ns

Sine Wave Characteristics

(1.2 GS/s clock, 32 waveform points, 37.5 MHz signal frequency) (600 MS/s clock, 32 waveform points, 18.75 MHz signal frequency)

Harmonics

Normal: ≤-40 dBc (2.0 Vp-p),

Direct ≤=-49 dBc (0.6 Vp-p)

Normal: ≤-46 dBc (2.0 Vp-p),

Direct ≤=-55 dBc (0.6 Vp-p)

Non Harmonics

Normal: ≤-60 dBc (2.0 Vp-p, DC to 600 MHz)

Normal: ≤-60 dBc (2.0 Vp-p, DC to 300 MHz)

Phase noise

≤-85 dBc/Hz (2.0 Vp-p, 10 kHz offset) ≤-85 dBc/Hz (2.0 Vp-p, 10 kHz offset)

SFDR

56 dBc (Normal, 18.75 MHz, 600 MS/s, 2.0 Vp-p)

60 dBc (Normal, 10 MHz, 600 MS/s, 1.0 Vp-p)

80 dBc (Normal, 1 MHz, 600 MS/s, 1.0 Vp-p)

64 dBc (Direct, 10 MHz, 600 MS/s, 0.6 Vp-p)

80 dBc (Direct, 1 MHz, 600 MS/s, 0.6 Vp-p)


Заказать Tektronix AWG5002